Part Number Hot Search : 
LC7560 LS411060 P1015 PC3500 C1410 RT9385 W78C33BM SD2100
Product Description
Full Text Search
 

To Download APS75-30 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 APS75-30
Outline
Specification
APS75-30
Safety standard
MEET APPROVE APPROVE Low Voltage Directive UL1950,CSA950 EN60950 TUV
80
Derating Curve
Outline drawing
APS75-30 was developed to meet AS-Interface (Actuator Sensor Interface) requirement. AS-Interface is a kind of international open network for FA application as the actuator-sensor level of the architecture. AS-Interface applies one cable only that supplies the signal and electric power stably together, so that will make cost saving and cable reduction possible.
Output Derating Curve
100
..
C-UL
MOUNTING : STANDARD MOUNTING ONLY LOAD(%)
60 40 20 0
AS-i
APPROVE APPROVE EN50295 AS-i AS-International Association(No.37901)
EMC Feature
AS-Interface Power Supply Global scale wide input range: AC85-264V Output: 30V 2.4A max. DIN rail mountable type
CONFORM CONFORM CONFORM EN55011-B, EN55022-B VCCI-B FCC-B
-10
0
10
20
30
40
50
60
Ta
Immunity : Comform to EN50082-2 EN61000-4-2 Electrostatics discharge EN61000-4-3 Radiated electromagnetic field EN61000-4-4 Electrical fast transient EN61000-4-5 Surge EN61000-4-6 Induced electromagnetic field
DIN EN50022 35X7.5 Input Terminal
(Please refer to Instruction manual before use)
LED 60 12.22 7.5 7.5 7.5 7.5
135.6
APS75-30 Specifications
MODEL ITEM 1. Nominal Output Voltage
1
APS75-30
30VDC 0A
9.75
2. Minimum Output Current 3. Maximum Output Current 4. Maximum Output Power 5. Efficiency (Typ) 6. Input Voltage Range 7. Input Frequency 8. Input Current(100/200VAC)(Typ) 9. Inrush Current(Typ) 10. Output Voltage Range 11. Maximum Ripple & Noise 12. Initial Setting Voltage (*4) (*1) (*3) (*1) (*2)
72W 80% 85 50Hz 1.9A Fixed 150m Vpp 1% 2% 2.8A 115% 0.2mA(Typ) at 100VAC 0.45mA(Typ) at 230VAC 20ms at 100VAC -10 30% -30 10% +50 90%RH +85 95%RH No dewdrop 20mA at 25 , Input - Output: 3kVAC 20mA Output - FG: 500VDC 100mA for 1 min : 100%, +55 : 70% No dewdrop 4.8A 264VAC 60Hz (47Hz 63Hz) , Cold Start 1.2A (1.6A at 115VAC)
104 114.1 1.5
R3 .3
2
8.6 12 19.4 16.75
Input Terminal
45.5
1
Unit:mm
18A at 100VAC, 40A at 230VAC, Ta=25
APS75-30 Instruction Manual
BEFORE USING THIS PRODUCT
These operating instructions do not purport to cover all details or variation in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the Purchaser s purposes, the matter should be referred to the local Sales Office. The contents of these operating instructions shall not become part or modify any prior or existing agreement, commitment or relationship. The Sales Contract contains the entire obligations. The warranty contained in the contract between the parties is the sole warranty. Any statements contained herein do not create new warranties or modify the existing warranty.
13. Maximum Line & Load (*5) & temperature Regulation 14. Over Current Protection 16. Leakage Current 17. Hold-up Time (Typ) 18. Operating Temperature 19. Operating Humidity 20. Storage Temperature 21. Storage Humidity 22. Cooling 23. Withstand Voltage 24. Isolation Resistance 25. Vibration 26. Shock 27. Safety 28. Conducted Emission 29. Radiated Emission 30. Immunity 31. Impulse Noise Simulation 32. Degree of Protection 33. Weight(Typ.) 34. Size (W H D) IEC529 IEC68-2-6 IEC68-2-27 (*6) (*8) (*9) (*10)
15. Over Voltage Protection(Typ) (*7)
DANGER
For the purpose of this operating instructions and product labels,"Danger " indicates death, severe personal injury or substantial property damage will result if proper precautions are not taken.
WARNING
For the purpose of this operating instructions and product labels,"Warning" indicates death, severe personal injury or substantial property damage can result it proper precautions are not taken.
Convection Cooling Input - FG: 2kVAC More than 100M and 70%RH, Output - FG...500VDC
CAUTION
For the purpose of this operating instructions and product labels, "Caution" indicates minor personal injury or property damage can result if proper precautions are not taken.
Mounting DIN rail : 10Hz 55Hz, Half-wave Amplitude 0.5mm (1 hour), Mounting screw: 10Hz 55Hz, Half-wave Amplitude 1mm (1 hour) Mounting DIN rail : 150m/s2 (11ms), Mounting screw: 300m/s2 (18ms) Apploved by UL1950, CSA950(C-UL), EN60950(TUV), Built to meet EN50295(AS-i) Built to meet EN55011-B, EN55022-B, FCC-ClassB, VCCI-B Built to meet EN55011-B, EN55022-B, FCC-ClassB, VCCI-B Built to meet EN50082-2, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6 Noise Voltage : 2kV (Nomal, Common), pulse Width : 1us (Pulse Rise 1ns) IP20 620g 45 135 105 mm (Refer to Outline Drawing)
1. Terminal Explanation
1 2 3 4 5 6 7
=NOTES= *1 At 100/200VAC,Ta = 25 and maximum output power. *2 For cases where conformance to various safety specs (UL,CSA,EN) are required, input voltage range will be 100~230VAC(50/60Hz). *3 Not applicable for the in-rush current to Noise Filter less than 0.2ms. *4 Measure with JEITA RC-9131 probe, Bandwise of scope : 100MHz, and Please refer to Fig. A for measurement of ripple voltage. *5 85~264VAC,constant load at Line Regulation. No load-full load at Load Regulation. *6 Constant current limit with automatic recovery. Avoid to operate over load or dead short for 30seconds. *7 OVP circuit will shutdown output, manual reset. *8 Measure by the each measuring method of UL,CSA,EN (at 60Hz). *9 At 100VAC maximum output current. *10 Refer to OUTPUT DERATING CURVE (BB018-01-03_)
Basic Connection
AS-i LineGND AS-I+
8
Measurement point for ripple Voltage
9
L1 : Input terminal Live line N : Input terminal Neutral line FG : Frame Ground POWER INDICATOR LED (Lights green during power output) AS-i + : AS-i Output terminal AS-i + : AS-i Output terminal Live GND : Live ground (Isolated from input FG) AS-i AS-i Output terminal AS-i AS-i Output terminal
0.1uF A Fig. A
2.5
2.4A
51.1
96.7
7.5 7.5


▲Up To Search▲   

 
Price & Availability of APS75-30

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X